Sprinter designs and installs single-mode and multi-mode fiber for backbone infrastructure, inter-building connectivity, and high-bandwidth applications — fusion spliced, OTDR tested, and fully documented.
Campus backbone between buildings, WAN links, inter-facility connectivity, telco handoffs.
Required when runs exceed 300m or when single-strand WDM is planned.
MDF to IDF backbone, data center interconnects, intra-building high-speed links.
OM4 or OM5 recommended for all new installations.
Precision fusion splicing for permanent, low-loss fiber joints. We carry field fusion splicers on every fiber job — no mechanical splice substitutions.
Optical Time Domain Reflectometer testing characterizes every span — splice loss, connector loss, total attenuation, and fault location. You get the full trace file.
For speed-sensitive installations, we use MTP/MPO pre-terminated trunk cables with field-verified polarity.
Wall-mount and rack-mount fiber enclosures, LC/SC patch panels, and splice trays — neatly dressed and clearly labeled.
Riser, plenum, and armored fiber for indoor applications. Direct-burial and aerial lashing for outdoor runs between buildings.
Single-mode or multi-mode fiber runs to high-performance workstations, editing suites, or where EMI makes copper impractical.
Connecting MDF to remote IDFs across a multi-building campus.
High-density inter-rack and cross-connect fiber in server rooms.
Fiber uplinks from camera clusters to the core network — eliminates distance limits of copper.
EMI-immune runs across factory floors near VFDs and large motors.
Backbone connecting multiple clinical buildings with deterministic latency.
Between buildings, parking structures, or across parking lots.
Cat6, Cat6A, and fiber structured cabling for commercial facilities.
Explore Data Cabling10GbE and PoE++ ready cabling for new construction and retrofits.
Explore Cat6A InstallationIDF/MDF buildouts, rack installations, and full port documentation.
Explore Network InfrastructureOur Work
Single-mode and multi-mode fiber — fusion-spliced, OTDR tested, and documented for the long haul.
Photo 1
Fusion splicer in use on a job site
Photo 2
OTDR test results on a tech's screen
Photo 3
Fiber patch panel terminated in an LIU
Photo 4
Outside-plant fiber pull between buildings
Photo 5
Aerial or underground fiber install
Photo 6
Completed fiber backbone in a clean rack
More project photos coming soon.
Single-mode or multi-mode, indoor or outdoor — we design the right fiber system for your building and deliver every meter fusion-spliced and OTDR verified.
Or call us: 888-711-9669